Assay Method Information |
|
| MGAT LCMS Assay |
Description: | The MGAT enzyme reactions were performed in CORNING Falcon 96-well Polypropylene plates, in a total volume of 60 uL of 50 mM Potassium Phosphate buffer pH 7.4, containing a final concentration of 100 uM 2-oleoylglycerol, 15 uM oleoyl-Coenzyme A and 0.0013 ug/uL Human or Mouse MGAT-2 or 0.0026 ug/uL Rat recombinant MGAT-2 membranes expressed in Sf9 cells. Assay plates were run through a fully automated robotics system and shaken for 5 seconds every minute for a total 10 minutes. The reactions were then quenched with 120 uL of ice cold methanol containing 1 ug/mL 1,2-distearoyl-rac-glycerol as the internal standard. Plates were shaken for 2 minutes and spun down to remove protein precipitation. After the spin, samples were transferred to LC/MS compatible PCR plates. For LC/MS analysis, a ThermoFisher Surveyor pump, utilizing a Waters Symmetry C8, 50x2.1 mm column, was used for the chromatography of enzyme products. |
Affinity data for this assay | |
---|---|
If you find an error in this entry please send us an E-mail |
Home |
| |
Search |
| |
Deposit |
| |
SiteMap |
| |
About us |
| |
Email us |
| |
Info |
|
©2000 BindingDB. All rights reserved. |