Assay Name:  Isothermal Titration Calorimetry (ITC)
Description:  ITC experiments were carried out at an enzyme [E] concentration of 25-50 μM with 0.25-1 mM compound [I] concentration in the KDM5 storage buffer with ~500 μM MnCl2 and 10% (v/v) DMSO. A MicroCal Auto-iTC200 was used to perform 25 4-μL injections of compounds into protein or buffer (to measure the heat of dilution)